Fluke 414D/62 MAX+ Laser Distance Meter/Infrared Thermometer Combo Kit
Key features
The 414D reduces errors, saves time and money
- The most advanced laser technology for distance measurement
- Measures up to 50 m (165 ft) with accuracy of 2 mm (0.08 in)
- Quick calculation of area (square feet/meters) and volume
- Pythagoras function indirectly measures height via two other measurements
- Stores up to five measurement results
- Battery life of 3000 measurements with automatic shut-off feature
Fluke 62 MAX+. Small in size. Big on toughness
- Dust and water-resistant: IP54 rated
- Rugged: 3-meter (9.8-foot) drop tested
- Ergonomically designed: Completely redesigned for a more natural hand fit
- Distance to spot: 12:1
- Dual lasers: Identifies area to be measured
- Large, backlit display: Makes data easier to read, even in dark areas
The 414D reduces errors, saves time and money
- The most advanced laser technology for distance measurement
- Measures up to 50 m (165 ft) with accuracy of 2 mm (0.08 in)
- Quick calculation of area (square feet/meters) and volume
- Pythagoras function indirectly measures height via two other measurements
- Stores up to five measurement results
- Battery life of 3000 measurements with automatic shut-off feature
Fluke 62 MAX+. Small in size. Big on toughness
- Dust and water-resistant: IP54 rated
- Rugged: 3-meter (9.8-foot) drop tested
- Ergonomically designed: Completely redesigned for a more natural hand fit
- Distance to spot: 12:1
- Dual lasers: Identifies area to be measured
- Large, backlit display: Makes data easier to read, even in dark areas
Specifications: Fluke 414D/62 MAX+ Laser Distance Meter/Infrared Thermometer Combo Kit
Fluke 414D Laser Distance Meter
Distance Measurement Typical Measuring Tolerance ¹ ±2.0 mm ³ Maximum Measuring Tolerance ² ±3.0 mm ³ Range At Leica Target Plate GZM26 50 m / 165 ft Typical Range ¹ 40 m / 130 ft Range At Unfavorable Condition 4 35 m / 115 ft Smallest Unit Displayed 1 mm / 1/16 in Ø Laser Point At Distances 6 / 30 / 60 mm
(10 / 50 / 100 m) Tilt Measurement Measuring Tolerance To Laser Beam 5 No Measuring Tolerance To Housing 5 No Range No General Laser Class 2 Laser Type 635 nm, < 1 mW Protection Class IP40 Automatic Laser Off After 90 seconds Automatic Power Off After 180 seconds Battery Life (2 x AAA) 1.5 V NEDA 24A/IEC LR03 Up to 3,000 measurements Size (L x W x D) 116 x 53 x 33 mm Weight (with batteries) 113 g Temperature Range:
Storage Operation -25 °C to +70 °C (-13 °F to +158 °F) 0 °C to +40 °C (32 °F to +104 °F) Calibration Cycle Not applicable Maximum Altitude 3000 m Maximum Relative Humidity 85% at 20 °F to 120 °F (-7 °C to 50 °C) Safety IEC Standard No. 61010-1:2001 EN60825-1:2007 (Class II) EMC EN 55022:2010 EN 61000-4-3:2010 EN 61000-4-8:2010 1. Applies for 100% target reflectivity (white painted wall), low background illumination, 25 °C.
2. Applies for 10 to 500% target reflectivity, high background illumination, -10 °C to +50 °C.
3. Tolerances apply from 0.05 m to 10 m with a confidence level of 95%. The maximum tolerance may deteriorate to 0.1 mm/m between 10 m to 30 m and to 0.15 mm/m for distances above 30 m.
4. Applies for 100% target reflectivity, background illumination between 10'000 lux and 30'000 lux.
5. After user calibration. Additional angle related deviation of ±0.01 ° per degree up to ±45 ° in each quadrant. Applies at room temperature. For the whole operating temperature range the maximum deviation increases by ±0.1 °
Fluke 62 MAX+ Infrared Thermometer
Specifications Temperature Range -30 °C to 650 °C (-22 °F to 1202 °F) Accuracy ±1.0 °C or ±1.0% of reading, whichever is greater -10 °C to 0 °C: ±2.0 -30 °C to -10 °C: ±3.0 Response Time (95%) Fluke 62 MAX+ < 300 ms (95% of reading) Spectral response 8 to 14 microns Emissivity 0.10 to 1.00 Optical Resolution 12:1 (calculated at 90% energy) Display Resolution 0.1 °C (0.2 °F) Repeatability Of Readings ±0.5% of reading or < ±0.5 °C (1 °F), whichever is greater Power AA battery Battery Life 8 hours with laser and backlight on Physical Specifications Weight 255 g (8.99 oz) Size (L x W x D) 175 x 85 x 75 mm (6.88 x 3.34 x 2.95 in) Operating Temperature 0 °C to 50 °C (32 °F to 122 °F) Storage Temperature (Without Battery) -20 °C to 60 °C (-4 °F to 140 °F) Operating Humidity 10% to 90% RH non-condensing at 30 °C (86 °F) Operating Altitude 2000 meters above mean sea level Storage Altitude 12,000 meters above mean sea level IP Rating IP 54 per IEC 60529 Drop Test 3 meters Vibration And Shock IEC 68-2-6 2.5 g, 10 to 200 Hz IEC 68-2-27, 50 g, 11 ms EMC EN 61326-1:2006 EN 61326-2:2006 Standards And Agency Approval Compliance EN/IEC 61010-1: 2001 Laser Safety FDA and EN 60825-1 Class II
Fluke 414D Laser Distance Meter
| Distance Measurement | |
| Typical Measuring Tolerance ¹ | ±2.0 mm ³ |
| Maximum Measuring Tolerance ² | ±3.0 mm ³ |
| Range At Leica Target Plate GZM26 | 50 m / 165 ft |
| Typical Range ¹ | 40 m / 130 ft |
| Range At Unfavorable Condition 4 | 35 m / 115 ft |
| Smallest Unit Displayed | 1 mm / 1/16 in |
| Ø Laser Point At Distances | 6 / 30 / 60 mm (10 / 50 / 100 m) |
| Tilt Measurement | |
| Measuring Tolerance To Laser Beam 5 | No |
| Measuring Tolerance To Housing 5 | No |
| Range | No |
| General | |
| Laser Class | 2 |
| Laser Type | 635 nm, < 1 mW |
| Protection Class | IP40 |
| Automatic Laser Off | After 90 seconds |
| Automatic Power Off | After 180 seconds |
| Battery Life (2 x AAA) 1.5 V NEDA 24A/IEC LR03 | Up to 3,000 measurements |
| Size (L x W x D) | 116 x 53 x 33 mm |
| Weight (with batteries) | 113 g |
| Temperature Range: Storage Operation | -25 °C to +70 °C (-13 °F to +158 °F) |
| 0 °C to +40 °C (32 °F to +104 °F) | |
| Calibration Cycle | Not applicable |
| Maximum Altitude | 3000 m |
| Maximum Relative Humidity | 85% at 20 °F to 120 °F (-7 °C to 50 °C) |
| Safety | IEC Standard No. 61010-1:2001 |
| EN60825-1:2007 (Class II) | |
| EMC | EN 55022:2010 |
| EN 61000-4-3:2010 | |
| EN 61000-4-8:2010 | |
| 1. Applies for 100% target reflectivity (white painted wall), low background illumination, 25 °C. 2. Applies for 10 to 500% target reflectivity, high background illumination, -10 °C to +50 °C. 3. Tolerances apply from 0.05 m to 10 m with a confidence level of 95%. The maximum tolerance may deteriorate to 0.1 mm/m between 10 m to 30 m and to 0.15 mm/m for distances above 30 m. 4. Applies for 100% target reflectivity, background illumination between 10'000 lux and 30'000 lux. 5. After user calibration. Additional angle related deviation of ±0.01 ° per degree up to ±45 ° in each quadrant. Applies at room temperature. For the whole operating temperature range the maximum deviation increases by ±0.1 ° | |
Fluke 62 MAX+ Infrared Thermometer
| Specifications | ||
| Temperature Range | -30 °C to 650 °C (-22 °F to 1202 °F) | |
| Accuracy | ±1.0 °C or ±1.0% of reading, whichever is greater | |
| -10 °C to 0 °C: ±2.0 | ||
| -30 °C to -10 °C: ±3.0 | ||
| Response Time (95%) | Fluke 62 MAX+ | < 300 ms (95% of reading) |
| Spectral response | 8 to 14 microns | |
| Emissivity | 0.10 to 1.00 | |
| Optical Resolution | 12:1 (calculated at 90% energy) | |
| Display Resolution | 0.1 °C (0.2 °F) | |
| Repeatability Of Readings | ±0.5% of reading or < ±0.5 °C (1 °F), whichever is greater | |
| Power | AA battery | |
| Battery Life | 8 hours with laser and backlight on | |
| Physical Specifications | ||
| Weight | 255 g (8.99 oz) | |
| Size (L x W x D) | 175 x 85 x 75 mm (6.88 x 3.34 x 2.95 in) | |
| Operating Temperature | 0 °C to 50 °C (32 °F to 122 °F) | |
| Storage Temperature (Without Battery) | -20 °C to 60 °C (-4 °F to 140 °F) | |
| Operating Humidity | 10% to 90% RH non-condensing at 30 °C (86 °F) | |
| Operating Altitude | 2000 meters above mean sea level | |
| Storage Altitude | 12,000 meters above mean sea level | |
| IP Rating | IP 54 per IEC 60529 | |
| Drop Test | 3 meters | |
| Vibration And Shock | IEC 68-2-6 2.5 g, 10 to 200 Hz | |
| IEC 68-2-27, 50 g, 11 ms | ||
| EMC | EN 61326-1:2006 | |
| EN 61326-2:2006 | ||
| Standards And Agency Approval | ||
| Compliance | EN/IEC 61010-1: 2001 | |
| Laser Safety | FDA and EN 60825-1 Class II | |
Fluke 414D/62 MAX+ Laser Distance Meter/Infrared Thermometer Combo Kit
- Product Code:Fluke 414D/62 MAX+ Laser Distance
- Availability:In Stock
Tags: FLUKE

สินค้าของเรา
ไม้ชักฟิวส์แรงสูง·เครื่องกำเนิดไฟฟ้า·รอกยกของ·ไม้ชักฟิวส์·ไม้ฉนวน·บันไดสไลด์·มีดปอกสาย·ชุดประกอบฉนวนค้ำยันสายไฟ·Ratchet and Coffing Hoist·LINGHTING ARRESTER 25-26 KV. 5kA. PREISE·Drop out Fuse Cutout Cover·Electrical installation equisment·WWW.KANDP.CO.TH·Cutout Bracket type ANSI TR202·K & P INTEKTRADE CO.LTD·Disconnecting Switch Barrier·Drop out 27 KV. 100.A 8kA "U-TAH"·Ratchet Cable Cutter· Insulator Cover·InsulatedHanger·Conductor Cutter with Insulated Handles·Conductor Cover 46 kv·Clamp stick grip all type ขนาด 8 ฟุต·Clamp Stick grip all type ขนาด 12 ฟุต·สว่านไร้สาย·ล้อวัดระยะทาง·ประแจบล๊อคไฟฟ้าไร้สาย (BRUSHLESS CORDLESS IMPACT WRENCH)·เทปวัดระยะชนิดโลหะ·ตู้แผงสวิตช์·ตู้เก็บเครื่องมือ·เครื่องอัดลมใช้มอเตอร์ไฟฟ้า·เครื่องมือบีบหลอดต่อสายไฮดรอลิค·เครื่องมือบีบคอนเนคเตอร์ แบบ H·เครื่องมือต่อสายลงดิน (Grounding Equipment)·เครื่องมือจับและดึงสาย (Wire Grip Come Along) Overall outside·เครื่องดึงสาย (Coffing Hoist)·อุปกรณ์ระบบไฟฟ้า·สวิตซ์ตัดตอนแรงสูง·หางปลา·หลอดต่อสาย·สลักเข้าปลายสาย·พีจีคอนเนคเตอร์·ฉนวนป้องกันไฟฟ้าลัดวงจร·ฉนวนครอบล่อฟ้า·เครื่องมือช่างไฟฟ้าอุตสาหกรรม·เครื่องมือไฮดรอลิก·เครื่องมือแบตเตอรี่ไร้สายดิสคอนเนคติ้งสวิตซ์แบริเออร์·ฉนวนครอบบุชชิ่ง·ตาข่าย·แผ่นอลูมิเนียม·ฉนวนครอบดรอปเอาท์ฟิวส์·หนามป้องกันสัตว์·อุปกรณ์ระบบไฟฟ้า·หม้อแปรง·Grip-all Clamp Stick·High Voltage Equipment·อุปกรณ์ติดตั้งระบบไฟฟ้าแรงสูง Pole Cover·Conductor Cover·Drop out cover·Telescopic Hot Stick·สินค้ารอกดึงสายไฟฟ้า R.I.K (Made in Thailand ผลิตสินค้าในไทย)·ไฟฟ้า·ROADMAPTOSTRONGGRIDLV·แคล้มป์สติ๊ก·ClampStick·เชือกใยยักษ์·เชือก Blue Polypopelene Handline 16mm·KNIPEX·เครื่องตรวจจับแรงดันไฟฟ้า·UNI·สายกันตก·UNI9103·เข็มขัดปีนเสา·YQK·SME·ขายดี·หมวกปีกรอบ·KPIR DISCONNECT STICK·หมวกนิรภัย S-Guard·MSA V-Gard full brim·คีมตัดสาย·คัทเตอร์ตัดสาย·CableCutter·คีมตัดลวดเหล็ก·คัทเตอร์เฟืองทด·คัทเตอร์ตัดสายเคเบิ้ล·คีมย้ำ·คีมบีบ·แคล้มป์สติ๊ก·KANDP·Milwaukee·CHANCE·RITZ·KUDOS·ZUPPER· FLUKE·Klauke Hydraulic Crimp Tool·Google·
Official Facebook Page
เนื้อหาส่วนนี้อาจไม่แสดงกรณีใช้ผ่านมือถือบางรุ่น ทางบริษัทฯ ขออภัยในความไม่สะดวก