Fluke 190 Series III ScopeMeter® Test Tools
Specifications: Fluke 190 Series III ScopeMeter® Test Tools
Oscilloscope Models | |||||||
190-062 | 190-102 | 190-202 | 190-502 | 190-104 | 190-204 | 190-504 | |
Vertical deflection | |||||||
Number of channels | 2 | 2 | 2 | 2 | 4 | 4 | 4 |
Bandwidth | 60 MHz | 100 MHz | 200 MHz | 500 MHz | 100 MHz | 200 MHz | 500 MHz |
Rise time | 5.8 ns | 3.5 ns | 1.7 ns | 0.7 ns | 3.5 ns | 1.7 ns | 0.7 ns |
Number of scope inputs | 2 input channels plus external trigger | 4 input channels | |||||
Channel architecture | All inputs fully insulated from each other and from ground. Inputs may be activated in any combination. | ||||||
Input coupling | AC or DC, with ground level indicator | ||||||
Input sensitivity | With 10:1 probe, 20 mV to 1000 V/div With 100:1 probe, 200 mV to 10 kV/div Direct (1:1), 2 mV to 100 V/div | ||||||
Bandwidth limiter | 20 MHz and 10 kHz | ||||||
Polarity | Normal, Inverted, Variable | ||||||
Input voltage | CAT III 1000 V/CAT IV 600 V rated, see General specifications for further details | ||||||
Vertical resolution | 8 bit | ||||||
Accuracy at 4 s to 10 μs/div | 5 mV/div to 100 V/div, ±(1.5 % + 6 counts) 2 mV/div, ±(1.5 % + 10 counts) | ||||||
Input impedance | 1 MΩ (± 1 %) // 15 pF (± 2.25 pF) | ||||||
Horizontal | |||||||
Maximum real- time sample rate (sampled simultaneously) | 625 MS/s (each channel) | 1.25 GS/s (each channel) | 2.5 GS/s (each channel) | 5 GS/s (single channel) or 2.5 GS/s (dual channel) | 1.25 GS/s (each channel) | 2.5 GS/s (2ch) 1.25 GS/s (4ch) | 5 GS/s (single ch) or 2.5 GS/s (2ch) or 1.25 GS/s (4ch) |
Record length | Up to 10,000 samples per channel | ||||||
Time base range | 10 ns/div to 4 s/div | 5 ns/div to 4 s/div | 2 ns/div to 4 s/div | 1 ns/div to 4 s/div | 5 ns/div to 4 s/div | 2 ns/div to 4 s/div | 1 ns/div to 4 s/div |
Time base in a 1-2-4-sequence Slower time/division settings using ScopeRecord™ Roll mode (see ‘Recorder mode’) | |||||||
Maximum record length | 10,000 samples per channel in scope mode 30,000 points per channel in ScopeRecord™ Roll mode (see ‘Recorder mode’) | ||||||
Timing accuracy | ± (0.01 % of reading + 1 pixel) | ||||||
Glitch capture | 8 ns (10 µs/div to 2 min/div) | ||||||
Display and acquisition | |||||||
Display | 133 mm x 90 mm (5.3 in x 3.5 in) full-color high brightness LCD | ||||||
Display modes | Any combination of channels; average on/off; replay. | ||||||
Visible screen width | 12 divisions horizontally in scope mode | ||||||
Digital persistence modes | Off, short, medium, long, infinite and envelope mode | ||||||
Waveform mathematics | One (190-xx2) or two (190-x04) mathematical operations on 2 input channels (A and B, C and D): add, subtract, multiply; X-Y-mode; Frequency Spectrum using FFT | ||||||
Acquisition modes | Normal, Averaged, Auto, Single Shot, ScopeRecord™ roll, glitch capture, waveform compare with automatic “Pass/Fail testing”; Replay | ||||||
Trigger and delay | |||||||
Source | Input A, B or External (via meter input) | Input A, B, C or D | |||||
Modes | Automatic, Edge, Pulse Width, N-Cycle, External (190-xx2) | ||||||
Connect-and- View™ | Advanced automatic triggering that recognizes signal patterns, automatically sets up and continuously adjusts triggering, time base and amplitude. Automatically displays stable waveforms of complex and dynamic signals like motor drive and control signals. Can be switched off if preferred. | ||||||
Pulse width triggering (on channel A) | Pulse width qualified by time Allows for triggering | ||||||
Time delay | 1 full screen of pre-trigger view or up to 100 screens (=1,200 divisions) of post-trigger delay | ||||||
Dual slope triggering | Triggers on both rising and falling edges alike | ||||||
N-cycle triggering | Triggers on N-th occurrence of a trigger event; N to be set in the range 2 to 99 | ||||||
Automatic capture of 100 screens | |||||||
When in oscilloscope mode, the instrument ALWAYS memorizes the last 100 screens—no specific user setup required. When an anomaly is seen, the REPLAY button can be pressed to review the full sequence of screen events over and over. Instrument can be set up for triggering on glitches or intermittent anomalies and will operate in “baby-sit” mode capturing 100 specified events. | |||||||
Replay | Manual or continuous replay. Displays the captured 100 screens as a “live” animation, or under manual control. Each screen has date and time-stamp. | ||||||
Replay storage | Ten sets of 100 screens each can be saved internally for later recall and analysis. Direct storage of additional sets on external flash memory drive through USB host port. | ||||||
FFT—frequency spectrum analysis | |||||||
Shows frequency content of oscilloscope waveform using Fast Fourier Transform | |||||||
Window | Automatic, Hamming, Hanning or None | ||||||
Automatic window | Digitally re-samples acquired waveform to get optimum frequency resolution in FFT resultant. | ||||||
Vertical scale | Linear/Logarithmic (in volts or amps) | ||||||
Frequency axis | Frequency range automatically set as a function of timebase range of oscilloscope | ||||||
Waveform compare and pass/fail testing | |||||||
Waveform compare | Provides storage and display of a reference waveform for visual comparison with newly acquired waveforms. Reference is derived from an acquired waveform and can be modified in the oscilloscope. | ||||||
Pass/Fail testing | In waveform compare mode, the oscilloscope can be set up to store only matching (“Pass”) or only non-matching (“Fail”) acquired waveforms in the replay memory bank for further analysis. | ||||||
Automatic scope measurements | |||||||
V dc, V ac rms, V ac+dc, Vpeak max, Vpeak min, Vpeak to peak, A ac, A dc, A ac+dc, frequency (in Hz), rise time (using cursors), fall time (using cursors), Power Factor (PF), Watts, VA, VA reactive, phase (between 2 inputs A&B or C&D), pulse width (pos./neg.), duty cycle (pos./ neg.), temperature °C, temperature °F (not for Japan), dBV, dBm into 50 Ω and 600 Ω, VPWM ac and VPWM(ac+dc) for measurement on pulse width modulated motor drives and frequency inverters, V/Hz ratio; | |||||||
Advanced power and motor drive functions | V/Hz ratio, Power Factor (PF), Watts, VA, VA reactive, V-PWM (ac) and V-PWM (ac+dc) for measure- ment on pulsewidth modulated motordrives and frequency inverters | ||||||
Cursor measurements | |||||||
Source | On any input waveform or on mathematical resultant waveform (excl. X-Y-mode) | ||||||
Dual horizontal lines | Voltage at cursor 1 and at cursor 2, voltage between cursors | ||||||
Dual vertical lines | Time between cursors, 1/T between cursors (in Hz), voltage between markers, risetime with markers, falltime with markers; Vrms between cursors, Watts between cursors. | ||||||
Single vertical line | Min-Max and Average voltage at cursor position; frequency and rms-value of individual frequency component in the FFT Resultant | ||||||
Advanced functions | mA*s (current-over-time, between cursors); V*s (voltage-over-time, between cursors); W*s (energy, between cursors) | ||||||
ZOOM | Ranges from full record overview to zoom in up to sample level, at any record length. |
Meter modes | |||||||
190-062 | 190-102 | 190-202 | 190-502 | 190-104 | 190-204 | 190-504 | |
Meter inputs | Via 4 mm banana inputs, fully isolated from scope inputs and scope ground | Via BNC scope inputs | |||||
Number of readings | One at a time via DMM input | Up to 4 automatic scope measurements simultaneously | |||||
Maximum resolution | 5,000 counts | ± 999 counts (frequency: 9999 counts) | |||||
Input impedance | 1 MΩ (± 1 %) // 14 pF (± 1.5 pF) | 1 MΩ (± 1 %) // 15 pF (± 2.25 pF) | |||||
Advanced meter functions | Auto/manual ranging, relative measurements (Zero reference), TrendPlot™ recording | ||||||
The specified accuracy is valid over the temperature range 18 °C to 28 °C Add 10 % of specified accuracy for each degree C below 18 °C or above 28 °C | |||||||
Voltage | |||||||
V dc accuracy | ± (0.5 % + 6 counts) | ± (1.5 % + 6 counts) | |||||
V ac true rms accuracy | |||||||
15 Hz to 60 Hz | ± (1 % + 10 counts) | ± (1.5 % + 10 counts) | |||||
60 Hz to 1 kHz | ± (2.5 % + 15 counts) | — | |||||
60 Hz to 20 kHz | — | ± (2.5 % + 15 counts) | |||||
V ac+dc true rms accuracy | |||||||
15 Hz to 60 Hz | ± (1 % + 10 counts) | ± (1.5 % + 10 counts) | |||||
60 Hz to 1 kHz | ± (2.5% + 15 counts) | — | |||||
60 Hz to 20 kHz | — | ± (2.5 % + 15 counts) | |||||
Voltmeter ranges | 500 mV, 5 V, 50 V, 500 V, 1,100 V | ||||||
Resistance | |||||||
Ranges | 500 Ω, 5 kΩ, 50 kΩ, 500 kΩ, 5 MΩ, 30 MΩ | — | |||||
Accuracy | ± (0.6 % + 6 counts) | — | |||||
Other meter functions | |||||||
Continuity | Beeper on < 50 Ω (± 30 Ω) | — | |||||
Diode test | Up to 2.8 V | — | |||||
Current (A) | A dc, A ac, A ac+dc using an optional current clamp or shunt Scaling factors: 0.1 mV/A, 1 mV/A to 100 V/A and 400 mV/A | ||||||
Temperature | With optional accessories. Scale factors 1mV/°C or 1mV/°F |