Fluke T6-600 Electrical Tester
Specifications: Fluke T6-600 Electrical Tester
Measurement Specifications Function Requires test leads Range Resolution Accuracy[1] FieldSense
ac voltage true-rms No 600 V 1 V ±(3% + 3 counts) 45 Hz - 66 Hz[2] [3] FieldSense
ac current true-rms No 200.0 A 0.1 A ±(3% + 3 counts) 45 Hz - 66 Hz Volts ac true-rms Yes 600 V 1 V ±(1.5% + 2 counts) 45 Hz - 66 Hz Volts dc Yes 600 V 1 V ±(1% + 2 counts) Resistance Yes 2000 Ω 1 Ω ±(1% + 2 counts) Safety 600 V CAT III Accuracy[1]: ± ( [ % of reading] + [number of least significant digits] ). Accuracy is specified for 1 year after calibration, at 18 °C to 28 °C (64 °F to 82 °F) with relative humidity to 90 %. AC measurements are ac-coupled, RMS responding.
Accuracy[2]: Add 3 % without an external ground connection. External ground connection required for user wearing insulated gloves, standing on an insulated ladder, or otherwise insulated from earth ground.
Accuracy[3]: FieldSense is specified from 16 V to 100 % of range.
General Specifications Calibration 1-year calibration cycle Dimensions 61.1 x 259.3 x 43.8 mm Jaw opening 17.8 mm Weight 0.35 kg (0.78 lb) Temperature Operating -10 °C to +50 °C (14 °F to 122 °F) Storage -30 °C to +60 °C (-22 °F to +140 °F) Altitude Operating 2,000 m (6,562 feet) Storage 10,000 m (32,808 feet) Relative Humidity 0% to 90%, 5 °C to 30 °C (41 °F to 86 °F) 0% to 75%, 30°C to 40 °C (86 °F to 104 °F) 0% to 45%, 40°C to 50 °C (104 °F to 122 °F) Battery Type and Life 2 x AA (IEC LR6); 360 hours continuous, typical; 200 hours using FieldSense Temperature coefficient 0.1 x (specified accuracy) / °C for <18°C or >28 °C (< 64.4 °F or > 82.4 °F) Safety IEC/EN 61010-1: Pollution Degree 2 Electromagnetic Environment IEC/EN 61326-1: Portable
Function | Requires test leads | Range | Resolution | Accuracy[1] |
---|---|---|---|---|
FieldSense ac voltage true-rms | No | 600 V | 1 V | ±(3% + 3 counts) 45 Hz - 66 Hz[2] [3] |
FieldSense ac current true-rms | No | 200.0 A | 0.1 A | ±(3% + 3 counts) 45 Hz - 66 Hz |
Volts ac true-rms | Yes | 600 V | 1 V | ±(1.5% + 2 counts) 45 Hz - 66 Hz |
Volts dc | Yes | 600 V | 1 V | ±(1% + 2 counts) |
Resistance | Yes | 2000 Ω | 1 Ω | ±(1% + 2 counts) |
Safety | 600 V CAT III | |||
Accuracy[1]: ± ( [ % of reading] + [number of least significant digits] ). Accuracy is specified for 1 year after calibration, at 18 °C to 28 °C (64 °F to 82 °F) with relative humidity to 90 %. AC measurements are ac-coupled, RMS responding. Accuracy[2]: Add 3 % without an external ground connection. External ground connection required for user wearing insulated gloves, standing on an insulated ladder, or otherwise insulated from earth ground. Accuracy[3]: FieldSense is specified from 16 V to 100 % of range. |
Calibration | 1-year calibration cycle | |
---|---|---|
Dimensions | 61.1 x 259.3 x 43.8 mm | |
Jaw opening | 17.8 mm | |
Weight | 0.35 kg (0.78 lb) | |
Temperature | Operating | -10 °C to +50 °C (14 °F to 122 °F) |
Storage | -30 °C to +60 °C (-22 °F to +140 °F) | |
Altitude | Operating | 2,000 m (6,562 feet) |
Storage | 10,000 m (32,808 feet) | |
Relative Humidity | 0% to 90%, 5 °C to 30 °C (41 °F to 86 °F) | |
0% to 75%, 30°C to 40 °C (86 °F to 104 °F) | ||
0% to 45%, 40°C to 50 °C (104 °F to 122 °F) | ||
Battery Type and Life | 2 x AA (IEC LR6); 360 hours continuous, typical; 200 hours using FieldSense | |
Temperature coefficient | 0.1 x (specified accuracy) / °C for <18°C or >28 °C | |
(< 64.4 °F or > 82.4 °F) | ||
Safety | IEC/EN 61010-1: Pollution Degree 2 | |
Electromagnetic Environment | IEC/EN 61326-1: Portable |
Fluke T6-600 Electrical Tester
- Product Code:Fluke T6-600 Electrical Tester
- Availability:In Stock
Tags: FLUKE
สินค้าของเรา
เครื่องกำเนิดไฟฟ้า ·
รอกยกของ · ไม้ชักฟิวส์ · ไม้ฉนวน · บันไดสไลด์ · มีดปอกสาย
· ชุดประกอบฉนวนค้ำยันสายไฟ · Ratchet Hoist แบบผ้าใบ · Ratchet Cable Cutter · Insulator Cover · InsulatedHanger
· Conductor Cutter with Insulated Handles · Conductor Cover 46 kv · Clamp stick grip
all type ขนาด 8 ฟุต · Clamp Stick
grip all type ขนาด 12 ฟุต · สว่านไร้สาย · ล้อวัดระยะทาง · ประแจบล๊อคไฟฟ้าไร้สาย (BRUSHLESS CORDLESS IMPACT WRENCH) · เทปวัดระยะชนิดโลหะ · ตู้แผงสวิตช์ · ตู้เก็บเครื่องมือ · เครื่องอัดลมใช้มอเตอร์ไฟฟ้า ·
เครื่องมือบีบหลอดต่อสายไฮดรอลิค · เครื่องมือบีบคอนเนคเตอร์
แบบ H · เครื่องมือต่อสายลงดิน (Grounding Equipment)
· เครื่องมือจับและดึงสาย (Wire Grip Come Along) Overall
outside · เครื่องดึงสาย (Coffing Hoist) · อุปกรณ์ระบบไฟฟ้า
· สวิตซ์ตัดตอนแรงสูง · หางปลา · หลอดต่อสาย · สลักเข้าปลายสาย · พีจีคอนเนคเตอร์ · ฉนวนป้องกันไฟฟ้าลัดวงจร ·
ฉนวนครอบล่อฟ้า · เครื่องมือช่างไฟฟ้าอุตสาหกรรม · เครื่องมือไฮดรอลิก · เครื่องมือแบตเตอรี่ไร้สายดิสคอนเนคติ้งสวิตซ์แบริเออร์
· ฉนวนครอบบุชชิ่ง · ตาข่าย · แผ่นอลูมิเนียม · ฉนวนครอบดรอปเอาท์ฟิวส์ · หนามป้องกันสัตว์ · อุปกรณ์ระบบไฟฟ้า · หม้อแปรงไฟฟ้า · ROADMAPTOSTRONGGRIDLV · แคล้มป์สติ๊ก
· ClampStick · เชือกใยยักษ์ · เชือก Handline
· KNIPEX · เครื่องตรวจจับแรงดันไฟฟ้า · UNI · สายกันตก · UNI9103 · เข็มขัดปีนเสา · YQK ·
SME · ขายดี · หมวกปีกรอบ · หมวกนิรภัย S-Guard · MSA V-Gard full brim · คีมตัดสาย · คัทเตอร์ตัดสาย · CableCutter · คีมตัดลวดเหล็ก ·
คัทเตอร์เฟืองทด · คัทเตอร์ตัดสายเคเบิ้ล ·
คีมย้ำ · คีมบีบ · แคล้มป์สติ๊ก
·
KANDP
Official Facebook Page
เนื้อหาส่วนนี้อาจไม่แสดงกรณีใช้ผ่านมือถือบางรุ่น ทางบริษัทฯ ขออภัยในความไม่สะดวก
4 TOP Facebook Official Page Post
เนื้อหาส่วนนี้อาจไม่แสดงกรณีใช้ผ่านมือถือบางรุ่น ทางบริษัทฯ ขออภัยในความไม่สะดวก