Fluke 414D/62 MAX+ Laser Distance Meter/Infrared Thermometer Combo Kit
Key features
The 414D reduces errors, saves time and money
- The most advanced laser technology for distance measurement
- Measures up to 50 m (165 ft) with accuracy of 2 mm (0.08 in)
- Quick calculation of area (square feet/meters) and volume
- Pythagoras function indirectly measures height via two other measurements
- Stores up to five measurement results
- Battery life of 3000 measurements with automatic shut-off feature
Fluke 62 MAX+. Small in size. Big on toughness
- Dust and water-resistant: IP54 rated
- Rugged: 3-meter (9.8-foot) drop tested
- Ergonomically designed: Completely redesigned for a more natural hand fit
- Distance to spot: 12:1
- Dual lasers: Identifies area to be measured
- Large, backlit display: Makes data easier to read, even in dark areas
The 414D reduces errors, saves time and money
- The most advanced laser technology for distance measurement
- Measures up to 50 m (165 ft) with accuracy of 2 mm (0.08 in)
- Quick calculation of area (square feet/meters) and volume
- Pythagoras function indirectly measures height via two other measurements
- Stores up to five measurement results
- Battery life of 3000 measurements with automatic shut-off feature
Fluke 62 MAX+. Small in size. Big on toughness
- Dust and water-resistant: IP54 rated
- Rugged: 3-meter (9.8-foot) drop tested
- Ergonomically designed: Completely redesigned for a more natural hand fit
- Distance to spot: 12:1
- Dual lasers: Identifies area to be measured
- Large, backlit display: Makes data easier to read, even in dark areas
Specifications: Fluke 414D/62 MAX+ Laser Distance Meter/Infrared Thermometer Combo Kit
Fluke 414D Laser Distance Meter
Distance Measurement Typical Measuring Tolerance ¹ ±2.0 mm ³ Maximum Measuring Tolerance ² ±3.0 mm ³ Range At Leica Target Plate GZM26 50 m / 165 ft Typical Range ¹ 40 m / 130 ft Range At Unfavorable Condition 4 35 m / 115 ft Smallest Unit Displayed 1 mm / 1/16 in Ø Laser Point At Distances 6 / 30 / 60 mm
(10 / 50 / 100 m) Tilt Measurement Measuring Tolerance To Laser Beam 5 No Measuring Tolerance To Housing 5 No Range No General Laser Class 2 Laser Type 635 nm, < 1 mW Protection Class IP40 Automatic Laser Off After 90 seconds Automatic Power Off After 180 seconds Battery Life (2 x AAA) 1.5 V NEDA 24A/IEC LR03 Up to 3,000 measurements Size (L x W x D) 116 x 53 x 33 mm Weight (with batteries) 113 g Temperature Range:
Storage Operation -25 °C to +70 °C (-13 °F to +158 °F) 0 °C to +40 °C (32 °F to +104 °F) Calibration Cycle Not applicable Maximum Altitude 3000 m Maximum Relative Humidity 85% at 20 °F to 120 °F (-7 °C to 50 °C) Safety IEC Standard No. 61010-1:2001 EN60825-1:2007 (Class II) EMC EN 55022:2010 EN 61000-4-3:2010 EN 61000-4-8:2010 1. Applies for 100% target reflectivity (white painted wall), low background illumination, 25 °C.
2. Applies for 10 to 500% target reflectivity, high background illumination, -10 °C to +50 °C.
3. Tolerances apply from 0.05 m to 10 m with a confidence level of 95%. The maximum tolerance may deteriorate to 0.1 mm/m between 10 m to 30 m and to 0.15 mm/m for distances above 30 m.
4. Applies for 100% target reflectivity, background illumination between 10'000 lux and 30'000 lux.
5. After user calibration. Additional angle related deviation of ±0.01 ° per degree up to ±45 ° in each quadrant. Applies at room temperature. For the whole operating temperature range the maximum deviation increases by ±0.1 °
Fluke 62 MAX+ Infrared Thermometer
Specifications Temperature Range -30 °C to 650 °C (-22 °F to 1202 °F) Accuracy ±1.0 °C or ±1.0% of reading, whichever is greater -10 °C to 0 °C: ±2.0 -30 °C to -10 °C: ±3.0 Response Time (95%) Fluke 62 MAX+ < 300 ms (95% of reading) Spectral response 8 to 14 microns Emissivity 0.10 to 1.00 Optical Resolution 12:1 (calculated at 90% energy) Display Resolution 0.1 °C (0.2 °F) Repeatability Of Readings ±0.5% of reading or < ±0.5 °C (1 °F), whichever is greater Power AA battery Battery Life 8 hours with laser and backlight on Physical Specifications Weight 255 g (8.99 oz) Size (L x W x D) 175 x 85 x 75 mm (6.88 x 3.34 x 2.95 in) Operating Temperature 0 °C to 50 °C (32 °F to 122 °F) Storage Temperature (Without Battery) -20 °C to 60 °C (-4 °F to 140 °F) Operating Humidity 10% to 90% RH non-condensing at 30 °C (86 °F) Operating Altitude 2000 meters above mean sea level Storage Altitude 12,000 meters above mean sea level IP Rating IP 54 per IEC 60529 Drop Test 3 meters Vibration And Shock IEC 68-2-6 2.5 g, 10 to 200 Hz IEC 68-2-27, 50 g, 11 ms EMC EN 61326-1:2006 EN 61326-2:2006 Standards And Agency Approval Compliance EN/IEC 61010-1: 2001 Laser Safety FDA and EN 60825-1 Class II
Fluke 414D Laser Distance Meter
Distance Measurement | |
Typical Measuring Tolerance ¹ | ±2.0 mm ³ |
Maximum Measuring Tolerance ² | ±3.0 mm ³ |
Range At Leica Target Plate GZM26 | 50 m / 165 ft |
Typical Range ¹ | 40 m / 130 ft |
Range At Unfavorable Condition 4 | 35 m / 115 ft |
Smallest Unit Displayed | 1 mm / 1/16 in |
Ø Laser Point At Distances | 6 / 30 / 60 mm (10 / 50 / 100 m) |
Tilt Measurement | |
Measuring Tolerance To Laser Beam 5 | No |
Measuring Tolerance To Housing 5 | No |
Range | No |
General | |
Laser Class | 2 |
Laser Type | 635 nm, < 1 mW |
Protection Class | IP40 |
Automatic Laser Off | After 90 seconds |
Automatic Power Off | After 180 seconds |
Battery Life (2 x AAA) 1.5 V NEDA 24A/IEC LR03 | Up to 3,000 measurements |
Size (L x W x D) | 116 x 53 x 33 mm |
Weight (with batteries) | 113 g |
Temperature Range: Storage Operation | -25 °C to +70 °C (-13 °F to +158 °F) |
0 °C to +40 °C (32 °F to +104 °F) | |
Calibration Cycle | Not applicable |
Maximum Altitude | 3000 m |
Maximum Relative Humidity | 85% at 20 °F to 120 °F (-7 °C to 50 °C) |
Safety | IEC Standard No. 61010-1:2001 |
EN60825-1:2007 (Class II) | |
EMC | EN 55022:2010 |
EN 61000-4-3:2010 | |
EN 61000-4-8:2010 | |
1. Applies for 100% target reflectivity (white painted wall), low background illumination, 25 °C. 2. Applies for 10 to 500% target reflectivity, high background illumination, -10 °C to +50 °C. 3. Tolerances apply from 0.05 m to 10 m with a confidence level of 95%. The maximum tolerance may deteriorate to 0.1 mm/m between 10 m to 30 m and to 0.15 mm/m for distances above 30 m. 4. Applies for 100% target reflectivity, background illumination between 10'000 lux and 30'000 lux. 5. After user calibration. Additional angle related deviation of ±0.01 ° per degree up to ±45 ° in each quadrant. Applies at room temperature. For the whole operating temperature range the maximum deviation increases by ±0.1 ° |
Fluke 62 MAX+ Infrared Thermometer
Specifications | ||
Temperature Range | -30 °C to 650 °C (-22 °F to 1202 °F) | |
Accuracy | ±1.0 °C or ±1.0% of reading, whichever is greater | |
-10 °C to 0 °C: ±2.0 | ||
-30 °C to -10 °C: ±3.0 | ||
Response Time (95%) | Fluke 62 MAX+ | < 300 ms (95% of reading) |
Spectral response | 8 to 14 microns | |
Emissivity | 0.10 to 1.00 | |
Optical Resolution | 12:1 (calculated at 90% energy) | |
Display Resolution | 0.1 °C (0.2 °F) | |
Repeatability Of Readings | ±0.5% of reading or < ±0.5 °C (1 °F), whichever is greater | |
Power | AA battery | |
Battery Life | 8 hours with laser and backlight on | |
Physical Specifications | ||
Weight | 255 g (8.99 oz) | |
Size (L x W x D) | 175 x 85 x 75 mm (6.88 x 3.34 x 2.95 in) | |
Operating Temperature | 0 °C to 50 °C (32 °F to 122 °F) | |
Storage Temperature (Without Battery) | -20 °C to 60 °C (-4 °F to 140 °F) | |
Operating Humidity | 10% to 90% RH non-condensing at 30 °C (86 °F) | |
Operating Altitude | 2000 meters above mean sea level | |
Storage Altitude | 12,000 meters above mean sea level | |
IP Rating | IP 54 per IEC 60529 | |
Drop Test | 3 meters | |
Vibration And Shock | IEC 68-2-6 2.5 g, 10 to 200 Hz | |
IEC 68-2-27, 50 g, 11 ms | ||
EMC | EN 61326-1:2006 | |
EN 61326-2:2006 | ||
Standards And Agency Approval | ||
Compliance | EN/IEC 61010-1: 2001 | |
Laser Safety | FDA and EN 60825-1 Class II |
Fluke 414D/62 MAX+ Laser Distance Meter/Infrared Thermometer Combo Kit
- Product Code:Fluke 414D/62 MAX+ Laser Distance
- Availability:In Stock
Tags: FLUKE
สินค้าของเรา
เครื่องกำเนิดไฟฟ้า ·
รอกยกของ · ไม้ชักฟิวส์ · ไม้ฉนวน · บันไดสไลด์ · มีดปอกสาย
· ชุดประกอบฉนวนค้ำยันสายไฟ · Ratchet Hoist แบบผ้าใบ · Ratchet Cable Cutter · Insulator Cover · InsulatedHanger
· Conductor Cutter with Insulated Handles · Conductor Cover 46 kv · Clamp stick grip
all type ขนาด 8 ฟุต · Clamp Stick
grip all type ขนาด 12 ฟุต · สว่านไร้สาย · ล้อวัดระยะทาง · ประแจบล๊อคไฟฟ้าไร้สาย (BRUSHLESS CORDLESS IMPACT WRENCH) · เทปวัดระยะชนิดโลหะ · ตู้แผงสวิตช์ · ตู้เก็บเครื่องมือ · เครื่องอัดลมใช้มอเตอร์ไฟฟ้า ·
เครื่องมือบีบหลอดต่อสายไฮดรอลิค · เครื่องมือบีบคอนเนคเตอร์
แบบ H · เครื่องมือต่อสายลงดิน (Grounding Equipment)
· เครื่องมือจับและดึงสาย (Wire Grip Come Along) Overall
outside · เครื่องดึงสาย (Coffing Hoist) · อุปกรณ์ระบบไฟฟ้า
· สวิตซ์ตัดตอนแรงสูง · หางปลา · หลอดต่อสาย · สลักเข้าปลายสาย · พีจีคอนเนคเตอร์ · ฉนวนป้องกันไฟฟ้าลัดวงจร ·
ฉนวนครอบล่อฟ้า · เครื่องมือช่างไฟฟ้าอุตสาหกรรม · เครื่องมือไฮดรอลิก · เครื่องมือแบตเตอรี่ไร้สายดิสคอนเนคติ้งสวิตซ์แบริเออร์
· ฉนวนครอบบุชชิ่ง · ตาข่าย · แผ่นอลูมิเนียม · ฉนวนครอบดรอปเอาท์ฟิวส์ · หนามป้องกันสัตว์ · อุปกรณ์ระบบไฟฟ้า · หม้อแปรงไฟฟ้า · ROADMAPTOSTRONGGRIDLV · แคล้มป์สติ๊ก
· ClampStick · เชือกใยยักษ์ · เชือก Handline
· KNIPEX · เครื่องตรวจจับแรงดันไฟฟ้า · UNI · สายกันตก · UNI9103 · เข็มขัดปีนเสา · YQK ·
SME · ขายดี · หมวกปีกรอบ · หมวกนิรภัย S-Guard · MSA V-Gard full brim · คีมตัดสาย · คัทเตอร์ตัดสาย · CableCutter · คีมตัดลวดเหล็ก ·
คัทเตอร์เฟืองทด · คัทเตอร์ตัดสายเคเบิ้ล ·
คีมย้ำ · คีมบีบ · แคล้มป์สติ๊ก
·
KANDP
Official Facebook Page
เนื้อหาส่วนนี้อาจไม่แสดงกรณีใช้ผ่านมือถือบางรุ่น ทางบริษัทฯ ขออภัยในความไม่สะดวก
4 TOP Facebook Official Page Post
เนื้อหาส่วนนี้อาจไม่แสดงกรณีใช้ผ่านมือถือบางรุ่น ทางบริษัทฯ ขออภัยในความไม่สะดวก