Fluke ii905 Acoustic Imager
Key features
- Easy, fast, and safe visual detection of compressed gas leaks with LeakQ™️ mode including estimated leak size and cost.
- The 7" LCD touchscreen overlays a SoundMap™️ on visual images, facilitating rapid leak location identification.
- The integrated visual- and textual tagging and annotation functionalities offer important details to optimize reporting and follow-up actions.
- On-the-go wireless upload to Fluke Connect
- Easy, fast, and safe visual detection of compressed gas leaks with LeakQ™️ mode including estimated leak size and cost.
- The 7" LCD touchscreen overlays a SoundMap™️ on visual images, facilitating rapid leak location identification.
- The integrated visual- and textual tagging and annotation functionalities offer important details to optimize reporting and follow-up actions.
- On-the-go wireless upload to Fluke Connect
Specifications: Fluke ii905 Acoustic Imager
Specifications Sensors Frequency band 2 kHz to 65 kHz Detection range1 0.5 to > 70 meters
(1.6 to > 230 feet) Field of view (FOV) 63°± 5° Nominal frame rate 25 FPS Built-in digital camera (visible light) Field of view (FOV) 63°±5° Focus Fixed lens Zoom 3 x digital zoom Resolution 5 MP Display Size 7" LCD with backlight, sunlight readable Resolution 1280 x 800 (1,024,000 pixels) Touchscreen Capacitive Acoustic image SoundMapTM image Image storage Storage capacity 32 GB
(> 8,000 pictures / > 1,600 videos) Image format Blended visual and SoundMapTM .JPG or .PNG Video format Blended visual and SoundMapTM .MP4 Video length Up to 5 minutes Digital export USB-C for data transfer Acoustic measurements Measurement range (typical) 15.4 to 115.2 dB SPL
(± 1 dB SPL 2 kHz)
5.6 to 102.5 dB SPL
(± 2 dB SPL 19 kHz)
28.4 to 131.1 dB SPL
(± 1 dB SPL 35 kHz)
41.8 to 133.1 dB SPL
(± 3 dB SPL 52 kHz) Classification and quantification LeakQTM Leak size scale, Leak rate, and Leak cost estimation PDQ ModeTM – MecQTM – Auto max/min dB gain Auto or manual, user selectable Frequency band selection User selectable through user-made presets or manual entry Battery Battery Rechargeable and field replaceable Li-ion battery Battery life 6 hours Battery charging time ~3,5 hours Battery charging system Internal (USB-C) Software Ease of use Intuitive user interface Acoustics: Show dB scale On/Off Acoustics: Min/Max dB Manual/Auto Acoustics: Profiles Preset capture profiles Acoustics: High frequency – Acoustics: Multiple sources Show single or multiple sources Palette: Colors 3: Grayscale, Ironbow, and Blue-Red Palette: Overly transparency Yes: 1-100% Grayscale mode Yes Centerpoint markers On/Off Trend graphs Frequency and dB scale Spotmarkers dB level reading at center point of image Leak values Leak costs, Leak volume, LeakQTM scale (1-10)2 Master admin menu Yes Annotation Asset name; Asset ID; Asset type; Leak type; Gas type; Pressure Photo notes Up to 4 photos notes for reference Asset inspection status 'As left', 'As found', 'Undetermined' Asset ID Text input and automatic QR code based asset ID identification Actions annotation Action requirements, Action priority level, Action notes Other Operating conditions, Weather notes General specifications Tripod holder / connector Yes: 1/4"-20 USB 2 x USB-C Wireless Wifi Operating Temperature -10 to 40 °C (14 to 104 °F) Storage Temperature -20 to 70 °C (-4 to 158 °F) without batteries installed Relative humidity 10 to 95 % non-condensing Size (H x W x L) 186 mm x 322 mm x 68 mm (7.3 inches x 12.7 inches x 2.7 inches) Weight (battery included) 2 kg (4.4 pounds) Ingress Protection (IP) IP40 Warranty 2 year Fluke Premium Care Premium Care Standard3 Self-diagnostic notification Array-health test to identify when microphone array needs attention Supported languages Dutch, English, Finish, French, German, Italian, Japanese, Korean, Polish, Portuguese, Simplified Chinese, Spanish, Swedish, Traditional Chinese RoHS compliant Yes Safety General safety IEC 61010-1 Electromagnetic Compatibility (EMC) International IEC 61326-1: Portable Electromagnetic Environment IEC 61326-2-2 CISPR 11: Group 1, Class A Korea (KCC) Class A Equipment (Industrial Broadcasting and Communication) USA (FCC) 47 CFR 15 sub part B. This product is considered an exempt device per clause 15.103 ¹ Depending on ambient conditions
² 1-10 Scale (independent of Leak Type)
³ Subject to regional availability (www.fluke.com/premiumcare)
Specifications | ||
Sensors | ||
Frequency band | 2 kHz to 65 kHz | |
Detection range1 | 0.5 to > 70 meters (1.6 to > 230 feet) | |
Field of view (FOV) | 63°± 5° | |
Nominal frame rate | 25 FPS | |
Built-in digital camera (visible light) | ||
Field of view (FOV) | 63°±5° | |
Focus | Fixed lens | |
Zoom | 3 x digital zoom | |
Resolution | 5 MP | |
Display | ||
Size | 7" LCD with backlight, sunlight readable | |
Resolution | 1280 x 800 (1,024,000 pixels) | |
Touchscreen | Capacitive | |
Acoustic image | SoundMapTM image | |
Image storage | ||
Storage capacity | 32 GB (> 8,000 pictures / > 1,600 videos) | |
Image format | Blended visual and SoundMapTM .JPG or .PNG | |
Video format | Blended visual and SoundMapTM .MP4 | |
Video length | Up to 5 minutes | |
Digital export | USB-C for data transfer | |
Acoustic measurements | ||
Measurement range (typical) | 15.4 to 115.2 dB SPL (± 1 dB SPL 2 kHz) 5.6 to 102.5 dB SPL (± 2 dB SPL 19 kHz) 28.4 to 131.1 dB SPL (± 1 dB SPL 35 kHz) 41.8 to 133.1 dB SPL (± 3 dB SPL 52 kHz) | |
Classification and quantification | ||
LeakQTM | Leak size scale, Leak rate, and Leak cost estimation | |
PDQ ModeTM | – | |
MecQTM | – | |
Auto max/min dB gain | Auto or manual, user selectable | |
Frequency band selection | User selectable through user-made presets or manual entry | |
Battery | ||
Battery | Rechargeable and field replaceable Li-ion battery | |
Battery life | 6 hours | |
Battery charging time | ~3,5 hours | |
Battery charging system | Internal (USB-C) | |
Software | ||
Ease of use | Intuitive user interface | |
Acoustics: Show dB scale | On/Off | |
Acoustics: Min/Max dB | Manual/Auto | |
Acoustics: Profiles | Preset capture profiles | |
Acoustics: High frequency | – | |
Acoustics: Multiple sources | Show single or multiple sources | |
Palette: Colors | 3: Grayscale, Ironbow, and Blue-Red | |
Palette: Overly transparency | Yes: 1-100% | |
Grayscale mode | Yes | |
Centerpoint markers | On/Off | |
Trend graphs | Frequency and dB scale | |
Spotmarkers | dB level reading at center point of image | |
Leak values | Leak costs, Leak volume, LeakQTM scale (1-10)2 | |
Master admin menu | Yes | |
Annotation | Asset name; Asset ID; Asset type; Leak type; Gas type; Pressure | |
Photo notes | Up to 4 photos notes for reference | |
Asset inspection status | 'As left', 'As found', 'Undetermined' | |
Asset ID | Text input and automatic QR code based asset ID identification | |
Actions annotation | Action requirements, Action priority level, Action notes | |
Other | Operating conditions, Weather notes | |
General specifications | ||
Tripod holder / connector | Yes: 1/4"-20 | |
USB | 2 x USB-C | |
Wireless | Wifi | |
Operating Temperature | -10 to 40 °C (14 to 104 °F) | |
Storage Temperature | -20 to 70 °C (-4 to 158 °F) without batteries installed | |
Relative humidity | 10 to 95 % non-condensing | |
Size (H x W x L) | 186 mm x 322 mm x 68 mm (7.3 inches x 12.7 inches x 2.7 inches) | |
Weight (battery included) | 2 kg (4.4 pounds) | |
Ingress Protection (IP) | IP40 | |
Warranty | 2 year | |
Fluke Premium Care | Premium Care Standard3 | |
Self-diagnostic notification | Array-health test to identify when microphone array needs attention | |
Supported languages | Dutch, English, Finish, French, German, Italian, Japanese, Korean, Polish, Portuguese, Simplified Chinese, Spanish, Swedish, Traditional Chinese | |
RoHS compliant | Yes | |
Safety | ||
General safety | IEC 61010-1 | |
Electromagnetic Compatibility (EMC) International | IEC 61326-1: Portable Electromagnetic Environment IEC 61326-2-2 CISPR 11: Group 1, Class A | |
Korea (KCC) | Class A Equipment (Industrial Broadcasting and Communication) | |
USA (FCC) | 47 CFR 15 sub part B. This product is considered an exempt device per clause 15.103 | |
¹ Depending on ambient conditions ² 1-10 Scale (independent of Leak Type) ³ Subject to regional availability (www.fluke.com/premiumcare) |
Fluke ii905 Acoustic Imager
- Product Code:Fluke ii905 Acoustic Imager
- Availability:In Stock
Tags: FLUKE
สินค้าของเรา
เครื่องกำเนิดไฟฟ้า ·
รอกยกของ · ไม้ชักฟิวส์ · ไม้ฉนวน · บันไดสไลด์ · มีดปอกสาย
· ชุดประกอบฉนวนค้ำยันสายไฟ · Ratchet Hoist แบบผ้าใบ · Ratchet Cable Cutter · Insulator Cover · InsulatedHanger
· Conductor Cutter with Insulated Handles · Conductor Cover 46 kv · Clamp stick grip
all type ขนาด 8 ฟุต · Clamp Stick
grip all type ขนาด 12 ฟุต · สว่านไร้สาย · ล้อวัดระยะทาง · ประแจบล๊อคไฟฟ้าไร้สาย (BRUSHLESS CORDLESS IMPACT WRENCH) · เทปวัดระยะชนิดโลหะ · ตู้แผงสวิตช์ · ตู้เก็บเครื่องมือ · เครื่องอัดลมใช้มอเตอร์ไฟฟ้า ·
เครื่องมือบีบหลอดต่อสายไฮดรอลิค · เครื่องมือบีบคอนเนคเตอร์
แบบ H · เครื่องมือต่อสายลงดิน (Grounding Equipment)
· เครื่องมือจับและดึงสาย (Wire Grip Come Along) Overall
outside · เครื่องดึงสาย (Coffing Hoist) · อุปกรณ์ระบบไฟฟ้า
· สวิตซ์ตัดตอนแรงสูง · หางปลา · หลอดต่อสาย · สลักเข้าปลายสาย · พีจีคอนเนคเตอร์ · ฉนวนป้องกันไฟฟ้าลัดวงจร ·
ฉนวนครอบล่อฟ้า · เครื่องมือช่างไฟฟ้าอุตสาหกรรม · เครื่องมือไฮดรอลิก · เครื่องมือแบตเตอรี่ไร้สายดิสคอนเนคติ้งสวิตซ์แบริเออร์
· ฉนวนครอบบุชชิ่ง · ตาข่าย · แผ่นอลูมิเนียม · ฉนวนครอบดรอปเอาท์ฟิวส์ · หนามป้องกันสัตว์ · อุปกรณ์ระบบไฟฟ้า · หม้อแปรงไฟฟ้า · ROADMAPTOSTRONGGRIDLV · แคล้มป์สติ๊ก
· ClampStick · เชือกใยยักษ์ · เชือก Handline
· KNIPEX · เครื่องตรวจจับแรงดันไฟฟ้า · UNI · สายกันตก · UNI9103 · เข็มขัดปีนเสา · YQK ·
SME · ขายดี · หมวกปีกรอบ · หมวกนิรภัย S-Guard · MSA V-Gard full brim · คีมตัดสาย · คัทเตอร์ตัดสาย · CableCutter · คีมตัดลวดเหล็ก ·
คัทเตอร์เฟืองทด · คัทเตอร์ตัดสายเคเบิ้ล ·
คีมย้ำ · คีมบีบ · แคล้มป์สติ๊ก
·
KANDP
Official Facebook Page
เนื้อหาส่วนนี้อาจไม่แสดงกรณีใช้ผ่านมือถือบางรุ่น ทางบริษัทฯ ขออภัยในความไม่สะดวก
4 TOP Facebook Official Page Post
เนื้อหาส่วนนี้อาจไม่แสดงกรณีใช้ผ่านมือถือบางรุ่น ทางบริษัทฯ ขออภัยในความไม่สะดวก