Fluke 902 FC True-RMS HVAC Clamp Meter
Specifications: Fluke 902 FC True-RMS HVAC Clamp Meter
Function A ac (via Jaw) Resolution 0.1 A Accuracy 2.0% ±5 digit (45-65 Hz) 2.5% ±5 digit (65-400 Hz) Range 600.0 A Crest Factor (50Hz or 60Hz) 2.5 MIN@220 A
> 1.4 MIN@600 A
Add 2% for CF>400 A V ac Resolution 0.1 V Accuracy 1.5% ±5 digits Range 600.0 V V dc Resolution 0.1 V Accuracy 1.5% ±5 digits Range 600.0 V Ohms Resolution 0.1/1/10 Accuracy 1% ±5 digits Range 600/6000/60.00 kΩ Capacitance Resolution 0.1/1 µF Accuracy 1% ±4 digits Range 100.0/1000 µF µA Resolution 0.1 µA Accuracy 1% ±5 digits Range 200 µA Contact temperature Resolution 0.1 C/F Accuracy 1% ±8 digits Range -40 to 400 °C (-40 °F to 752 °F) Continuity beeper Beeper volume 75 dBA nom. 15 cm. from case front On threshold <=30 Ω Mechanical and General Specifications Maximum voltage between any terminal and earth ground 600 V Battery type 2 AA alkaline batteries, NEDA 15A, IEC LR6 Temperature Operating: -10 °C to +50 °C (14 °F to +122 °F)
Storage: -40 °C to +60 °C (-40 °F to +140 °F) Operating humidity Non condensing (< 10 °C [50 °F]), ≤90 % RH (at 10 °C to 30 °C [50 °F to 86 °F]), ≤75 % RH (at 30 °C to 40 °C (86 °F to 104 °F)), ≤45 % RH (at 40 °C to 50 °C (104 °F to 122 °F)) Altitude Operating: 3,000 m (9,842 ft)
Storage: 12,000 m (39,370 ft) Dimensions 230 x 83.7 x 45.4mm (9.06 x 3.30 x 1.39 in) Weight (meter only) 419 g (15 oz) Safety IEC 61010-1, Pollution Degree 2
IEC 61010-2-032: CAT III 600 V / CAT IV 300 V
IEC 61010-2-033: CAT III 600 V / CAT IV 300 V IP Rating IEC 60529: IP30, non-operating Radio Frequency Certification FCC ID:T68-FBLE IC:6627A-FBLE Electromagnetic Compatibility (EMC) International: IEC 61326-1: Portable, Electromagnetic Environment, IEC 61326-2-2 CISPR 11: Group 1, Class A Korea (KCC): Class A Equipment (Industrial Broadcasting & Communication Equipment) USA (FCC): 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103. Temperature coefficients Add 0.1 × specified accuracy for each degree C above 28 °C or below 18 °C
Function | ||
A ac (via Jaw) | ||
Resolution | 0.1 A | |
Accuracy | 2.0% ±5 digit (45-65 Hz) | |
2.5% ±5 digit (65-400 Hz) | ||
Range | 600.0 A | |
Crest Factor (50Hz or 60Hz) | 2.5 MIN@220 A > 1.4 MIN@600 A Add 2% for CF>400 A | |
V ac | ||
Resolution | 0.1 V | |
Accuracy | 1.5% ±5 digits | |
Range | 600.0 V | |
V dc | ||
Resolution | 0.1 V | |
Accuracy | 1.5% ±5 digits | |
Range | 600.0 V | |
Ohms | ||
Resolution | 0.1/1/10 | |
Accuracy | 1% ±5 digits | |
Range | 600/6000/60.00 kΩ | |
Capacitance | ||
Resolution | 0.1/1 µF | |
Accuracy | 1% ±4 digits | |
Range | 100.0/1000 µF | |
µA | ||
Resolution | 0.1 µA | |
Accuracy | 1% ±5 digits | |
Range | 200 µA | |
Contact temperature | ||
Resolution | 0.1 C/F | |
Accuracy | 1% ±8 digits | |
Range | -40 to 400 °C (-40 °F to 752 °F) | |
Continuity beeper | ||
Beeper volume | 75 dBA nom. 15 cm. from case front | |
On threshold | <=30 Ω | |
Mechanical and General Specifications | ||
Maximum voltage between any terminal and earth ground | 600 V | |
Battery type | 2 AA alkaline batteries, NEDA 15A, IEC LR6 | |
Temperature | Operating: -10 °C to +50 °C (14 °F to +122 °F) Storage: -40 °C to +60 °C (-40 °F to +140 °F) | |
Operating humidity | Non condensing (< 10 °C [50 °F]), ≤90 % RH (at 10 °C to 30 °C [50 °F to 86 °F]), ≤75 % RH (at 30 °C to 40 °C (86 °F to 104 °F)), ≤45 % RH (at 40 °C to 50 °C (104 °F to 122 °F)) | |
Altitude | Operating: 3,000 m (9,842 ft) Storage: 12,000 m (39,370 ft) | |
Dimensions | 230 x 83.7 x 45.4mm (9.06 x 3.30 x 1.39 in) | |
Weight (meter only) | 419 g (15 oz) | |
Safety | IEC 61010-1, Pollution Degree 2 IEC 61010-2-032: CAT III 600 V / CAT IV 300 V IEC 61010-2-033: CAT III 600 V / CAT IV 300 V | |
IP Rating | IEC 60529: IP30, non-operating | |
Radio Frequency Certification | FCC ID:T68-FBLE IC:6627A-FBLE | |
Electromagnetic Compatibility (EMC) | International: IEC 61326-1: Portable, Electromagnetic Environment, IEC 61326-2-2 CISPR 11: Group 1, Class A Korea (KCC): Class A Equipment (Industrial Broadcasting & Communication Equipment) USA (FCC): 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103. | |
Temperature coefficients | Add 0.1 × specified accuracy for each degree C above 28 °C or below 18 °C |
Fluke 902 FC True-RMS HVAC Clamp Meter
- Product Code:Fluke 902 FC True-RMS HVAC Clamp Meter
- Availability:In Stock
Tags: FLUKE
สินค้าของเรา
เครื่องกำเนิดไฟฟ้า ·
รอกยกของ · ไม้ชักฟิวส์ · ไม้ฉนวน · บันไดสไลด์ · มีดปอกสาย
· ชุดประกอบฉนวนค้ำยันสายไฟ · Ratchet Hoist แบบผ้าใบ · Ratchet Cable Cutter · Insulator Cover · InsulatedHanger
· Conductor Cutter with Insulated Handles · Conductor Cover 46 kv · Clamp stick grip
all type ขนาด 8 ฟุต · Clamp Stick
grip all type ขนาด 12 ฟุต · สว่านไร้สาย · ล้อวัดระยะทาง · ประแจบล๊อคไฟฟ้าไร้สาย (BRUSHLESS CORDLESS IMPACT WRENCH) · เทปวัดระยะชนิดโลหะ · ตู้แผงสวิตช์ · ตู้เก็บเครื่องมือ · เครื่องอัดลมใช้มอเตอร์ไฟฟ้า ·
เครื่องมือบีบหลอดต่อสายไฮดรอลิค · เครื่องมือบีบคอนเนคเตอร์
แบบ H · เครื่องมือต่อสายลงดิน (Grounding Equipment)
· เครื่องมือจับและดึงสาย (Wire Grip Come Along) Overall
outside · เครื่องดึงสาย (Coffing Hoist) · อุปกรณ์ระบบไฟฟ้า
· สวิตซ์ตัดตอนแรงสูง · หางปลา · หลอดต่อสาย · สลักเข้าปลายสาย · พีจีคอนเนคเตอร์ · ฉนวนป้องกันไฟฟ้าลัดวงจร ·
ฉนวนครอบล่อฟ้า · เครื่องมือช่างไฟฟ้าอุตสาหกรรม · เครื่องมือไฮดรอลิก · เครื่องมือแบตเตอรี่ไร้สายดิสคอนเนคติ้งสวิตซ์แบริเออร์
· ฉนวนครอบบุชชิ่ง · ตาข่าย · แผ่นอลูมิเนียม · ฉนวนครอบดรอปเอาท์ฟิวส์ · หนามป้องกันสัตว์ · อุปกรณ์ระบบไฟฟ้า · หม้อแปรงไฟฟ้า · ROADMAPTOSTRONGGRIDLV · แคล้มป์สติ๊ก
· ClampStick · เชือกใยยักษ์ · เชือก Handline
· KNIPEX · เครื่องตรวจจับแรงดันไฟฟ้า · UNI · สายกันตก · UNI9103 · เข็มขัดปีนเสา · YQK ·
SME · ขายดี · หมวกปีกรอบ · หมวกนิรภัย S-Guard · MSA V-Gard full brim · คีมตัดสาย · คัทเตอร์ตัดสาย · CableCutter · คีมตัดลวดเหล็ก ·
คัทเตอร์เฟืองทด · คัทเตอร์ตัดสายเคเบิ้ล ·
คีมย้ำ · คีมบีบ · แคล้มป์สติ๊ก
·
KANDP
Official Facebook Page
เนื้อหาส่วนนี้อาจไม่แสดงกรณีใช้ผ่านมือถือบางรุ่น ทางบริษัทฯ ขออภัยในความไม่สะดวก
4 TOP Facebook Official Page Post
เนื้อหาส่วนนี้อาจไม่แสดงกรณีใช้ผ่านมือถือบางรุ่น ทางบริษัทฯ ขออภัยในความไม่สะดวก